There are multiple challenges associated with the operation of an open recirculating cooling system. Warm water temperatures and evaporation drive bacterial growth and accumulation of solvents. Significant additions of chemicals, including biocides, are needed to handle Legionella risks and issues with corrosion, scaling and biofouling. Increasing awareness of Legionella and biocide risks has led to a need for alternative solutions.
In order to phase out biocides, Alleima Tubes in Sandviken has installed AquaWorker - industrial UV for process water.
The installation of AquaWorker at Alleima cooling system resulted in several important improvements:
Read the full case here pdf, 236.9 kB, opens in new window.
At Alleima Tubes, part of the continuous environmental work is to reduce the use of chemicals. For the furnace cooling system, the objective was to replace the use of biocides with UV treatment to control microbiological activity. The benefits are multiple; biological control, reduced OPEX, reduced health hazard risks of personnel and environment and waste stream compliance.
For the cooling system at Alleima Tubes, Wallenius Water Innovation made a system analysis based on cooling capacity, system volume and water analysis. In addition, factors such as operational parameters and installation point with presumed greatest effect was considered. One AquaWorker was installed and in full operation in September 2023. Since October 2023, the cooling system has been in operation without the use of biocides. Water samples have regularly been analyzed for bacteria activity.
Alleima's total annual savings amounted to 14 000 euro. The calculations include costs for biocides, electricity, spare parts and maintenance hours by personnel. The main savings are due to reduced consumption of biocides.
| Biocides only | AquaWorker in operation | |
| System data | Total volume=20 m³, Cooling flow rate=140 m³/h, Operation=330 days, 16h (not during nights)) | |
| Water treatment | Biocides 100% | UV treatment (no biocides) |
| Biocide dosage | 2 times/week | - |
| Bacteria levels | Bacteria levels below 104 CFU/ml | Bacteria levels below 104 CFU/ml |
| Transmittance of water | 11-35% (filter damaged) | 80-85% |
| Water/system appearance | Dirt, flakes, foam | Clear water |

Husqvarna in Sweden, manufactures and develops professional chainsaws and cutting tools. They have already automated many parts of their production to...

Latest technology brings better control and lower costs...

There are multiple challenges associated with the operation of an open recirculating cooling system. Warm water temperatures and evaporation drive bac...

There are several challenges associated with the operation of open recirculating cooling systems. Warm and humid conditions are ideal for the reproduc...

Momento is a world-leading supplier of impact sockets and accessories. To increase productivity and reduce costs, Momento installed several FluidWorke...

GKN ePowertrain manufactures and sells components for power transmission to the automotive industry. In 2022, GKN carried out long-term tests of Fluid...

Through automated cutting fluid handling with FluidWorker 150 , LK Precision has increased both its productivity and profitability. Read more about ...

Union Electric Åkers has since 2019 continuously invested in sustainable productivity with FluidWorker 100 automated fluid quality units in their o...
Book your free 20-minute session with one of our process fluid experts. Fill out the form and we’ll get back to you within two business days!